日期(qi):2015-09-18瀏(liu)覽:5063次
新能(neng)源汽(qi)車(che)充(chong)電(dian)樁(zhuang)技(ji)術要求(qiu)
1新能(neng)源汽(qi)車(che)充(chong)電(dian)樁(zhuang)簡(jian)介(jie)
充(chong)電(dian)樁(zhuang)(栓(shuan))能(neng)實(shi)現計(ji)時、計(ji)電度(du)、計(ji)金額(e)充(chong)電(dian),可以(yi)作(zuo)為(wei)市民購(gou)電(dian)終端(duan)。同(tong)時(shi)為提高公(gong)共(gong)充(chong)電(dian)樁(zhuang)(栓(shuan))的(de)效率(lv)和實用性,今後(hou)將(jiang)陸(lu)續(xu)增(zeng)加壹樁(zhuang)(栓(shuan))多(duo)充(chong)和(he)為電(dian)動(dong)自行(xing)車(che)充(chong)電(dian)的(de)功能。
充(chong)電(dian)站(zhan)電力(li)配(pei)套(tao)
⑴ 常(chang)規(gui)充(chong)電(dian)
① 典型常(chang)規(gui)充(chong)電(dian)站(zhan)的(de)規(gui)模(mo) ,壹般以(yi)20~40輛電動(dong)汽(qi)車(che)來(lai)配(pei)置壹個充(chong)電(dian)站(zhan),這(zhe)種(zhong)配(pei)置是(shi)考(kao)慮充(chong)分利用晚(wan)間谷(gu)電(dian)進行充(chong)電(dian),缺點(dian)是(shi)充(chong)電(dian)設備(bei)利用率(lv)低。在(zai)高峰(feng)時(shi)也考(kao)慮充(chong)電(dian),則可(ke)以(yi)60~80輛電動(dong)來(lai)配(pei)制(zhi)壹個充(chong)電(dian)站(zhan),缺點(dian)是(shi)充(chong)電(dian)成本上升(sheng),增加高峰(feng)負(fu)荷(he)。
② 充(chong)電(dian)站(zhan)電力(li)配(pei)套(tao)的(de)典型配(pei)置(前(qian)提(ti)充(chong)電(dian)櫃(gui)具有(you)諧(xie)波(bo)等(deng)處理功能)
⑵ 快(kuai)速充(chong)電(dian)
① 典型快(kuai)速充(chong)電(dian)站(zhan)的(de)規(gui)模(mo) ,壹般以(yi)同時(shi)向8輛電動(dong)汽(qi)車(che)充(chong)電(dian)來(lai)配(pei)置壹個充(chong)電(dian)站(zhan)。
② 充(chong)電(dian)站(zhan)電力(li)配(pei)套(tao)的(de)典型配(pei)置
⑶ 機(ji)械充(chong)電(dian)
①機械(xie)充(chong)電(dian)站(zhan)的(de)規(gui)模(mo)小(xiao)型機(ji)械充(chong)電(dian)站(zhan)可以(yi)結合常規(gui)充(chong)電(dian)站(zhan)建設同時(shi)考(kao)慮,可以(yi)根據(ju)需(xu)要選(xuan)擇更(geng)大(da)容(rong)量(liang)的(de)變壓(ya)器(qi)。大(da)型(xing)機(ji)械(xie)充(chong)電(dian)站(zhan)壹般以(yi)80~100組充(chong)電(dian)電池同(tong)時(shi)充(chong)電(dian)配(pei)置壹個大型(xing)機械(xie)充(chong)電(dian)站(zhan),主(zhu)要適(shi)用於(yu)出(chu)租(zu)車(che)行(xing)業(ye)或(huo)電(dian)池租(zu)賃行(xing)業(ye),壹天不間斷充(chong)可(ke)以(yi)完成對(dui)400組電池的(de)充(chong)電(dian)。
⑷ 便(bian)攜式充(chong)電(dian)
① 別(bie)墅 具備(bei)三相四線(xian)表(biao)計(ji),獨立的(de)停車庫,可(ke)以(yi)利用已(yi)有(you)的(de)住(zhu)宅(zhai)供(gong)電設施,從(cong)住(zhu)宅(zhai)配(pei)電(dian)箱(xiang)專(zhuan)門放(fang)壹路(lu)10mm2或16mm2的(de)線(xian)路(lu)至車庫的(de)插座,來(lai)提供(gong)便(bian)攜式充(chong)電(dian)電源。
② 壹般住(zhu)宅(zhai)具有(you)固(gu)定(ding)的(de)集中(zhong)停車庫,壹般要(yao)求(qiu)地(di)下(xia)停車庫(充(chong)電(dian)安全(quan)考(kao)慮),可以(yi)利用小(xiao)區(qu)原(yuan)有的(de)供(gong)電配(pei)套(tao)設施進(jin)行(xing)改造,必(bi)須根據(ju)小(xiao)區(qu)已(yi)有(you)的(de)負(fu)荷(he)容量(liang)來(lai)考(kao)慮,包括谷(gu)電(dian)的(de)負(fu)荷(he)。具體(ti)方案(an)應(ying)根據(ju)小(xiao)區(qu)的(de)供(gong)電設施、方案(an)以(yi)及小(xiao)區(qu)的(de)建築(zhu)環境(jing)具體(ti)來(lai)確(que)定。
2新能(neng)源汽(qi)車(che)充(chong)電(dian)樁(zhuang)種(zhong)類(lei)
充(chong)電(dian)樁(zhuang)(栓(shuan))可(ke)分為直(zhi)流(liu)充(chong)電(dian)樁(zhuang)(栓(shuan)),交(jiao)流充(chong)電(dian)樁(zhuang)(栓(shuan))和(he)交(jiao)直流(liu)壹體充(chong)電(dian)樁(zhuang)(栓(shuan))。
3新能(neng)源汽(qi)車(che)充(chong)電(dian)樁(zhuang)技(ji)術要求(qiu)
交(jiao)流式(shi)
交(jiao)流充(chong)電(dian)樁(zhuang)(栓(shuan))技(ji)術要求(qiu)
1、環(huan)境(jing)條件要(yao)求(qiu)
① 工作(zuo)環(huan)境溫度(du):-20℃~+50℃;
② 相對(dui)濕(shi)度(du):5%~95%;
③海(hai)拔高度(du):≤1000m;
④ 安裝(zhuang)地(di)點(dian):戶(hu)外(wai);
⑤ 抗(kang)震(zhen)能力(li):地(di)面(mian)水平加速度(du) 0.3g;
地(di)面(mian)垂直加速度(du) 0.15g;
設備(bei)應(ying)能(neng)承(cheng)受(shou)同時作(zuo)用(yong)持續三個正(zheng)弦(xian)波(bo),並且(qie)安(an)全(quan)系(xi)數應(ying)大(da)於(yu)1.67;
2、新能(neng)源汽(qi)車(che)充(chong)電(dian)樁(zhuang)結構要求(qiu)
① 交(jiao)流充(chong)電(dian)樁(zhuang)(栓(shuan))殼體應(ying)堅(jian)固;
② 結構上須防(fang)止手(shou)輕(qing)易(yi)觸及(ji)露(lu)電部分;
③ 交(jiao)流充(chong)電(dian)樁(zhuang)(栓(shuan))應(ying)選(xuan)用(yong)厚(hou)度(du)1.0以(yi)上鋼(gang)組合結構,表面(mian)采用浸塑(su)處理,並充(chong)分考(kao)慮散(san)熱(re)的(de)要(yao)求(qiu)。充(chong)電(dian)樁(zhuang)(栓(shuan))應(ying)有(you)良(liang)好(hao)的(de)防(fang)電(dian)磁(ci)幹擾的(de)屏(ping)蔽(bi)功能;
④ 充(chong)電(dian)樁(zhuang)(栓(shuan))應(ying)有(you)足(zu)夠(gou)的(de)支撐強(qiang)度(du),應(ying)提(ti)供(gong)必(bi)要設施,以(yi)保(bao)證能夠(gou)正(zheng)確(que)起(qi)吊(diao)、運(yun)輸(shu)、存(cun)放(fang)和安裝(zhuang)設備(bei),且應(ying)提(ti)供(gong)地(di)腳螺(luo)栓(shuan)孔;
⑤ 樁(zhuang)(栓(shuan))體(ti)底(di)部應(ying)固(gu)定(ding)安(an)裝(zhuang)在高於(yu)地(di)面(mian)不小(xiao)於(yu)200mm的(de)基座上(shang)。基座面(mian)積不應(ying)大(da)於(yu)500mm×500mm;
⑥ 樁(zhuang)(栓(shuan))體(ti)外(wai)殼應(ying)采(cai)用(yong)抗(kang)沖(chong)擊力(li)強(qiang)、防盜(dao)性能好(hao)、抗老化的(de)材質;
⑦ 非(fei)絕(jue)緣材料(liao)外(wai)殼應(ying)可(ke)靠(kao)接地(di);
3、新能(neng)源汽(qi)車(che)充(chong)電(dian)樁(zhuang)電(dian)源要(yao)求(qiu)
① 輸(shu)入(ru)電(dian)壓(ya):單(dan)相(xiang)220V;
② 輸(shu)出(chu)功率(lv):單(dan)相(xiang)220V/5KW;
③ 頻(pin)率(lv):50Hz±2Hz;
④ 允許(xu)電壓(ya)波(bo)動(dong)範圍為:單(dan)相(xiang)220V±15%;
4、新能(neng)源汽(qi)車(che)充(chong)電(dian)樁(zhuang)電(dian)氣(qi)要(yao)求(qiu)
① 插頭與(yu)插座正(zheng)確(que)連接確(que)認成(cheng)功後(hou),帶負(fu)載可分合電路(lu)方可(ke)閉(bi)合,實現(xian)對(dui)插座的(de)供(gong)電;
② 漏電保(bao)護(hu)裝(zhuang)置應(ying)安(an)裝(zhuang)在供(gong)電電纜進線(xian)側(ce);
③ 低壓(ya)配(pei)電(dian)設備(bei)及線(xian)路(lu)的(de)保(bao)護(hu)應(ying)滿足(zu)《低壓(ya)配(pei)電(dian)設計(ji)規(gui)範》(GB/50053)中(zhong)的(de)相(xiang)關(guan)規(gui)定(ding);
④ 對(dui)IT系統配(pei)電(dian)線(xian)路(lu),當*次接地(di)故障(zhang)時,應(ying)由絕(jue)緣監察裝(zhuang)置發(fa)出(chu)音響(xiang)或燈(deng)光(guang)信(xin)號(hao),當發生(sheng)第(di)二次異(yi)相(xiang)接地(di)故障(zhang)時應(ying)由過電流保(bao)護(hu)電(dian)器(qi)或(huo)漏(lou)電(dian)電(dian)流動(dong)作(zuo)保(bao)護(hu)器(qi)切(qie)斷故(gu)障(zhang)電路(lu);
⑤ 照明(ming)配(pei)電(dian)系(xi)統(tong)中(zhong),照(zhao)明(ming)和插座回(hui)路(lu)不宜由同壹回路(lu)供(gong)電。插座回(hui)路(lu)的(de)電(dian)源側(ce)應(ying)設置剩(sheng)余(yu) 電(dian)流(liu)動(dong)作(zuo)保(bao)護(hu)裝(zhuang)置,其(qi)額(e)定動(dong)作(zuo)電(dian)流為30mA;
6、新能(neng)源汽(qi)車(che)充(chong)電(dian)樁(zhuang)安(an)全(quan)防(fang)護(hu)功能
① 交(jiao)流充(chong)電(dian)樁(zhuang)(栓(shuan))應(ying)具備(bei)急停開(kai)關(guan),可通過手(shou)動(dong)或(huo)遠(yuan)方通(tong)信(xin)的(de)方式(shi)緊(jin)急(ji)停止充(chong)電(dian);
② 交(jiao)流充(chong)電(dian)樁(zhuang)(栓(shuan))應(ying)具備(bei)輸(shu)出(chu)側的(de)漏(lou)電(dian)保(bao)護(hu)功能;
③ 交(jiao)流充(chong)電(dian)樁(zhuang)(栓(shuan))應(ying)具備(bei)輸(shu)出(chu)側過流和短路(lu)保(bao)護(hu)功能;
④ 交(jiao)流充(chong)電(dian)樁(zhuang)(栓(shuan))應(ying)具有(you)阻(zu)燃(ran)功能;
7、新能(neng)源汽(qi)車(che)充(chong)電(dian)樁(zhuang)IP防(fang)護(hu)等(deng)級
交(jiao)流充(chong)電(dian)樁(zhuang)(栓(shuan))應(ying)遵守IP54(在室外),並配(pei)置必(bi)要的(de)防(fang)雨(yu)、防曬(shai)裝(zhuang)置;
8、三防(防(fang)潮(chao)濕(shi),防(fang)黴(mei)變,防鹽霧(wu)) 保(bao)護(hu)
充(chong)電(dian)機內(nei)印(yin)刷線(xian)路(lu)板、 接插件等(deng)電路(lu)應(ying)進(jin)行(xing)防(fang)潮(chao)濕(shi)、防(fang)黴(mei)變、防鹽霧(wu)處理,其(qi)中防(fang)鹽霧(wu)腐蝕能力(li)滿足(zu) GB/T 4797.6-1995《電(dian)工電子(zi)產(chan)品自然(ran)環(huan)境條件 塵、沙、鹽霧(wu)》中表9的(de)要(yao)求(qiu),使(shi)充(chong)電(dian)機能(neng)在室(shi)外(wai)潮(chao)濕(shi)、含(han)鹽霧(wu)的(de)環(huan)境(jing)下(xia)正(zheng)常運(yun)行;
9、防銹(防(fang)氧(yang)化)保(bao)護(hu)
充(chong)電(dian)樁(zhuang)(栓(shuan))鐵(tie)質外(wai)殼和暴(bao)露(lu)在外(wai)的(de)鐵(tie)質支架、零(ling)件應(ying)采(cai)取(qu)雙(shuang)層(ceng)防銹措施,非(fei)鐵(tie)質的(de)金屬(shu)外(wai)殼也應(ying)具有(you)防(fang)氧(yang)化保(bao)護(hu)膜(mo)或(huo)進(jin)行防(fang)氧(yang)化處理;
10、防(fang)風保(bao)護(hu)
安(an)裝(zhuang)在平(ping)臺上的(de)充(chong)電(dian)機以(yi)及暴(bao)露(lu)在外(wai)的(de)部件應(ying)能(neng)承(cheng)受(shou) GB/T 4797.5-9《電工電子(zi)產(chan)品自然(ran)環(huan)境條件降水和風》中表 9 規(gui)定(ding)的(de)不同地(di)區(qu)、不同高度(du)處相(xiang)對(dui)風速的(de)侵(qin)襲(xi);
11、防(fang)盜保(bao)護(hu)
電(dian)樁(zhuang)(栓(shuan))外(wai)殼門應(ying)裝(zhuang)防盜(dao)鎖,固定交(jiao)流充(chong)電(dian)樁(zhuang)(栓(shuan))的(de)螺(luo)栓(shuan)必(bi)須在(zai)打開(kai)外(wai)殼門後(hou)方能(neng)安(an)裝(zhuang)或拆(chai)卸;
12、新能(neng)源汽(qi)車(che)充(chong)電(dian)樁(zhuang)溫(wen)升(sheng)要求(qiu)
交(jiao)流充(chong)電(dian)樁(zhuang)(栓(shuan))在(zai)額(e)定負(fu)載長期連續運(yun)行,內(nei)部各(ge)發熱(re)元(yuan)器(qi)件及(ji)各(ge)部位溫(wen)升(sheng)應(ying)不超過Q/GDW 397\2009中表(biao)2規(gui)定(ding);
13、平(ping)均(jun)故障(zhang)間隔時間(MTBF)
MTBF應(ying)不小(xiao)於(yu)8760h;
14、安裝(zhuang)垂直傾(qing)斜度(du)不超過5%;
15、設備(bei)安裝(zhuang)地(di)點(dian)不得有(you)爆炸危險(xian)介(jie)質,周(zhou)圍介(jie)質不含有腐蝕金屬(shu)和(he)破壞(huai)絕(jue)緣的(de)有(you)害(hai)氣體(ti)及(ji)導(dao)電(dian)介(jie)質
直(zhi)流式(shi)
a) 充(chong)電(dian)樁(zhuang)(栓(shuan))電(dian)源輸(shu)入(ru)電(dian)壓(ya):三相四線(xian)380VAC±15%,頻(pin)率(lv)50Hz±5%;
b) 充(chong)電(dian)樁(zhuang)(栓(shuan))應(ying)滿足(zu)充(chong)電(dian)對(dui)象充(chong)電(dian)樁(zhuang)c) 充(chong)電(dian)樁(zhuang)(栓(shuan))輸(shu)出(chu)為直流電,輸(shu)出(chu)電壓(ya)滿足(zu)充(chong)電(dian)對(dui)象的(de)電(dian)池制(zhi)式(shi)要(yao)求(qiu);
d) zui大(da)輸(shu)出(chu)電流滿足(zu)充(chong)電(dian)對(dui)象的(de)電(dian)池制(zhi)式(shi)1C的(de)充(chong)電(dian)要求(qiu),並向(xiang)下(xia)兼(jian)容;
e) 充(chong)電(dian)方式(shi)分為常(chang)規(gui)和(he)快(kuai)速2種(zhong)方式(shi),常(chang)規(gui)為(wei)5小(xiao)時充(chong)電(dian)方式(shi),快(kuai)速為1小(xiao)時充(chong)電(dian)方式(shi)(針(zhen)對(dui)不同電池類(lei)型選(xuan)擇(ze));
f) 實(shi)現智(zhi)能IC管(guan)理;
g) 每個充(chong)電(dian)樁(zhuang)(栓(shuan))自帶(dai)操(cao)作(zuo)器(qi),以(yi)供(gong)用戶(hu)進(jin)行(xing)充(chong)電(dian)方式(shi)選(xuan)擇(ze)和操(cao)作(zuo)指(zhi)導(dao),並顯(xian)示(shi)電動(dong)車(che)電(dian)池狀(zhuang)態(tai)和(he)用(yong)戶(hu)IC卡(ka)資(zi)費(fei)信(xin)息(xi),實現(xian)無(wu)人(ren)管(guan)理;
h) 充(chong)電(dian)樁(zhuang)(栓(shuan))接口(kou)應(ying)符(fu)合GB/TXXXXXXXX電動(dong)汽(qi)車(che)傳(chuan)導(dao)式(shi)充(chong)電(dian)接口(kou)(暫(zan)行(xing))中(zhong)直流充(chong)電(dian)接口(kou)的(de)相(xiang)關(guan)規(gui)定(ding);
i) 充(chong)電(dian)樁(zhuang)(栓(shuan))通(tong)訊接口(kou)采用(yong)CAN通訊接口(kou),通信(xin)協(xie)議按照GB/TXXXXXXXX電(dian)動(dong)汽(qi)車(che)電(dian)池管(guan)理系(xi)統(tong)與非(fei)車載充(chong)電(dian)機之間(jian)的(de)通(tong)信(xin)協(xie)議(暫(zan)行(xing))的(de)規(gui)定(ding)執(zhi)行(xing)(充(chong)電(dian)對(dui)象為鋰(li)電(dian)池電(dian)動(dong)車(che));
j) 充(chong)電(dian)樁(zhuang)(栓(shuan))對(dui)充(chong)電(dian)過程(cheng)中的(de)非(fei)正(zheng)常狀(zhuang)態(tai)應(ying)具備(bei)相應(ying)的(de)報(bao)警和保(bao)護(hu)功能;
k) 充(chong)電(dian)樁(zhuang)(栓(shuan))對(dui)電池的(de)狀(zhuang)態(tai)要(yao)監控(kong),根據(ju)電(dian)池的(de)溫(wen)度(du),電壓(ya)對(dui)充(chong)電(dian)曲線(xian),充(chong)電(dian)電流(liu),充(chong)電(dian)壓(ya)自動(dong)調整;
l) 充(chong)電(dian)樁(zhuang)(栓(shuan))采(cai)用(yong)強(qiang)制風冷;
m) 充(chong)電(dian)樁(zhuang)(栓(shuan))防(fang)護(hu)等(deng)級符合《GB 4208-1993 外殼防護(hu)等(deng)級(IP代碼(ma))》IP54要(yao)求(qiu);
汽(qi)車(che)充(chong)電(dian)站(zhan)
現在能較好(hao)的(de)解(jie)決(jue)快(kuai)速充(chong)電(dian)問題(ti)的(de)方案(an)是(shi)-換電(dian)站(zhan)-利用給(gei)汽(qi)車(che)更(geng)換電(dian)池的(de)方法(fa)代(dai)替漫(man)長的(de)充(chong)電(dian)過程(cheng)。壹輛汽(qi)車(che)需(xu)要配(pei)備(bei)兩塊(kuai)電(dian)池,當壹塊電(dian)池用(yong)完後(hou)自動(dong)切(qie)換到(dao)另(ling)壹塊,此(ci)時(shi)可(ke)到(dao)換電(dian)站(zhan)將(jiang)用完的(de)電(dian)池換下(xia),裝(zhuang)上滿電(dian)的(de)電(dian)池。而(er)換下(xia)的(de)電(dian)池由電站(zhan)統壹充(chong)電(dian)和維(wei)護(hu),前(qian)提(ti)是(shi)充(chong)電(dian)站(zhan)要有相當數量的(de)備(bei)用電池。這(zhe)個方法(fa)優(you)點(dian)是(shi)快(kuai)速,用戶(hu)換完電池就(jiu)可(ke)以(yi)上路(lu),比加油都(dou)快(kuai)。用(yong)這(zhe)種(zhong)方法(fa)再(zai)加上停車場充(chong)電(dian)樁(zhuang)等(deng)輔(fu)助手(shou)段,相信(xin)電(dian)動(dong)汽(qi)車(che)的(de)普及就(jiu)近在(zai)眼(yan)前(qian)。
壹體式(shi)
概述(shu)
快(kuai)速充(chong)電(dian)樁(zhuang)(栓(shuan))設備(bei)采用交(jiao)直流(liu)壹體的(de)結構。既可實(shi)現直(zhi)流充(chong)電(dian),也可以(yi)交(jiao)流充(chong)電(dian)。白天(tian)充(chong)電(dian)業(ye)務多的(de)時(shi)候(hou),使(shi)用直流方式(shi)進(jin)行(xing)快(kuai)速充(chong)電(dian),當夜間(jian)充(chong)電(dian)站(zhan)用戶(hu)少(shao)時(shi)可(ke)用交(jiao)流充(chong)電(dian)進行(xing)慢(man)充(chong)操(cao)作(zuo)。
外(wai)形特點(dian)
1、人(ren)體(ti)工學設計(ji),充(chong)分考(kao)慮中國(guo)人(ren)特(te)點(dian),安(an)裝(zhuang)後(hou)整機高度(du)、屏(ping)幕(mu)高度(du)、鍵(jian)盤(pan)高度(du)、充(chong)電(dian)接頭安(an)放(fang)槽(cao)高度(du),適(shi)宜操(cao)作(zuo);
2、上(shang)出(chu)線(xian)口(kou)的(de)形式,節(jie)省(sheng)操(cao)作(zuo)者壹半的(de)體(ti)力(li);
3、考(kao)慮人的(de)使(shi)用(yong)習(xi)慣和(he)耐用性,采用(yong)觸摸(mo)和(he)鍵(jian)盤(pan)互為(wei)備(bei)份的(de)操(cao)控(kong),觸摸(mo)屏(ping)和(he)鍵(jian)盤(pan)采用(yong)防(fang)雨(yu)、防塵的(de)設計(ji);
4、具備(bei)緊急停機的(de)急(ji)停開(kai)關(guan);具備(bei)充(chong)電(dian)接頭安(an)放(fang)槽(cao),安(an)放(fang)槽(cao)可(ke)防(fang)水;5米長的(de)軟(ruan)電(dian)纜。
新能(neng)源汽(qi)車(che)充(chong)電(dian)樁(zhuang)功能特點(dian)
1、提(ti)供(gong)人機交(jiao)互操(cao)作(zuo);提(ti)供(gong)直流、交(jiao)流充(chong)電(dian)接口(kou);
2、具備(bei)語音提(ti)示(shi)功能;具備(bei)刷卡(ka)功能;
3、具備(bei)打印(yin)憑條的(de)功能;
4、和BMS實時(shi)通(tong)信(xin),獲取(qu)動(dong)力(li)電池類(lei)型、單(dan)體(ti)電壓(ya)、剩(sheng)余(yu)容(rong)量(liang)、溫度(du)、告警等(deng)信息(xi);
5、向充(chong)電(dian)機發(fa)生(sheng)控(kong)制指(zhi)令(ling)、開(kai)關(guan)信號(hao),控(kong)制充(chong)電(dian)機啟(qi)動(dong)與(yu)停止,獲取(qu)充(chong)電(dian)機狀(zhuang)態信(xin)息(xi);
6、具備(bei)充(chong)電(dian)接口(kou)的(de)連(lian)接狀(zhuang)態判斷、聯(lian)鎖(suo)、控(kong)制導(dao)引等(deng)完善的(de)安(an)全(quan)保(bao)護(hu)控(kong)制邏輯;
7、具備(bei)CAN2.0B、RS485通訊接口(kou),可以(yi)和集中(zhong)監控(kong)通信(xin),上(shang)送(song)充(chong)電(dian)狀態(tai)信息(xi);
8、具備(bei)漏電、短路(lu)、過壓(ya)、欠(qian)壓(ya)、過(guo)流等(deng)保(bao)護(hu)功能,確(que)保(bao)充(chong)電(dian)樁(zhuang)(栓(shuan))安(an)全(quan)可(ke)靠(kao)運(yun)行;防護(hu)等(deng)級IP54。
新能(neng)源汽(qi)車(che)充(chong)電(dian)樁(zhuang)計(ji)費系(xi)統
系統的(de)實(shi)現(xian)由三部分組成(cheng),下(xia)面(mian)分別(bie)進(jin)行(xing)介(jie)紹:
1、建設充(chong)電(dian)計(ji)費系(xi)統管(guan)理平(ping)臺,對(dui)系統涉及(ji)到(dao)的(de)基礎(chu)數據(ju)進(jin)行集中(zhong)式管(guan)理,例如(ru)電(dian)動(dong)汽(qi)車(che)信(xin)息(xi)、購電用戶(hu)信(xin)息(xi)、資(zi)產(chan)信(xin)息(xi)等(deng)。
2、建設充(chong)電(dian)計(ji)費系(xi)統運(yun)營平(ping)臺,用於(yu)對(dui)電動(dong)汽(qi)車(che)的(de)充(chong)放(fang)電及(ji)購電(dian)用(yong)戶(hu)的(de)充(chong)值(zhi)進行(xing)運(yun)營管(guan)理。
3、建設充(chong)電(dian)計(ji)費系(xi)統查詢(xun)平(ping)臺,用於(yu)對(dui)管(guan)理平(ping)臺及運(yun)營平(ping)臺產生(sheng)的(de)相(xiang)關(guan)數據(ju)進(jin)行綜合查詢(xun)
充(chong)電(dian)站(zhan)按照功能可以(yi)劃分為四個子模(mo)塊:配(pei)電(dian)系(xi)統(tong)、充(chong)電(dian)系統(tong)、電池調度(du)系統(tong)、充(chong)電(dian)站(zhan)監控(kong)系統(tong)。充(chong)電(dian)站(zhan)給汽(qi)車(che)充(chong)電(dian)壹般分為三種(zhong)方式(shi):普通充(chong)電(dian)、快(kuai)速充(chong)電(dian)、電池更(geng)換。
普通充(chong)電(dian)多為(wei)交(jiao)流充(chong)電(dian),可以(yi)使用(yong)220V或380V的(de)電(dian)壓(ya)。 快(kuai)速充(chong)電(dian)多為(wei)直流(liu)充(chong)電(dian)。充(chong)電(dian)站(zhan)主(zhu)要設備(bei)包括充(chong)電(dian)機、充(chong)電(dian)樁(zhuang)、有(you)源濾(lv)波(bo)裝(zhuang)置、電(dian)能監(jian)控(kong)系統(tong)。
新能(neng)源汽(qi)車(che)充(chong)電(dian)樁(zhuang)技(ji)術要求(qiu)基本參(can)數
滿足(zu)標(biao)準
新國(guo)標(biao)
連(lian)接器(qi)動(dong)力(li)線(xian)觸頭額(e)定電壓(ya)
DC750V
連(lian)接器(qi)動(dong)力(li)線(xian)觸頭額(e)定電流(liu)
12
連接器(qi)控(kong)制線(xian)觸頭電(dian)壓(ya)
DC36V
連(lian)接器(qi)控(kong)制線(xian)觸頭電(dian)流(liu)
連(lian)接器(qi)機(ji)械(xie)操(cao)作(zuo)壽(shou)命
≥10000次
防水等(deng)級
IP67
耐電壓(ya)
2000V
絕(jue)緣電阻(zu)
500MΩ
主(zhu)要的(de)形式 亭(ting)形式,可(ke)遮陽擋(dang)雨(yu),避免借(jie)口遭受(shou)雨(yu)淋 柱式,插口處有蓋子上(shang)翻(fan)
可移動(dong)式(shi) 地(di)下(xia)帶(dai)輪子可以(yi)自由推動(dong),主(zhu)要是(shi)裝(zhuang)載電池設備(bei)
壁掛(gua)式 掛(gua)在充(chong)電(dian)站(zhan)內(nei)墻上
柱掛(gua)式 掛(gua)在街(jie)上(shang)的(de)柱子上
小(xiao)結
1 充(chong)電(dian)柱體積不壹定要(yao)很(hen)大(da),可(ke)以(yi)有明(ming)顯的(de)提(ti)醒方式(shi)即(ji)可,如(ru)有(you)明(ming)顯的(de)放(fang)光(guang)的(de)logo
2 要(yao)做(zuo)好(hao)防銹,防(fang)雨(yu),防曬(shai),防(fang)漏(lou)電等(deng)措施,
3 可(ke)以(yi)考(kao)慮壹柱充(chong)多(duo)量汽(qi)車(che)的(de)形式
4 充(chong)電(dian)柱的(de)形式:嵌(qian)入地(di)面(mian)式,充(chong)電(dian)式就(jiu)是(shi)打開(kai)窨(xun)井(jing)蓋壹樣的(de)形式,與(yu)電線(xian)桿(gan)相互結合,停車場的(de)形式可(ke)以(yi)位於(yu)停車位(wei)上(shang)。 可升(sheng)降式(shi),可(ke)旋轉式